| Software specification:
Data Transmission Configuration: – Configure parameters for RS232 ports: + Speed: 115,200 bps + Data bits: 8 bits + Parity: None + Stop bits: 1 + Transmission mode: Full duplex – Configure parameters for RS422 ports: + Standard: TIA/DTA 422 + Transmission speed: 100 kbps to 10 Mbps + Available signal lines: Tx+, Tx−, Rx+, Rx− (full duplex) Integration with Functional Panels: – Acquire, aggregate, process, and transmit data via two RS232 ports – Route and transmit data via RS422 port – Check data integrity using CRC (Cyclic Redundancy Check) standard System Operation Configuration: – Define operating modes of the system based on pre-defined algorithms – Execute control algorithms to display error/failure notifications in different operating modes – Number of notification messages corresponding to diagnostic algorithms: not less than 360 System Integrity Check: – Aggregate and process signals related to the integrity status of panels and components in the system – Display test results Unlimited usage period. Supplied on 1 CDs (USD 5.00 per CDs included in price) |
Central Processing Software CENTRALCOM-360X
Description